Flink got minus one from a read call

WebMay 4, 2016 · Receiving "IO ERROR: Got minus one from a read call" when connecting to DB. K Brown May 4 2016 — edited May 7 2016. We have 2 12.1.0.2 databases running on the RAC cluster rac-clust. One (rac2db) is a 2 node RAC running on db1 and db2 and is admin-managed. The second (rac1db) is a single-node RAC running on db2 and is also … WebApr 11, 2024 · New issue flink oracle cdc Got minus one from a read call #1067 Open mrchenwx opened this issue on Apr 11, 2024 · 1 comment mrchenwx commented on Apr …

[Solved] oracle.net.ns.NetException: Got minus one from a read call

WebFlink is one of the few Amiga CD32 titles not to see a release for the Amiga home computer on which the CD32's hardware is based. The creators, Erwin Kloibhofer, Henk Nieborg, … WebApr 26, 2007 · It should be possible to read # this file and setup a Client by uncommenting parameter definitions # and substituting values. The comments should provide enough # explanation to enable a reasonable user to manage his TNS connections # without having to resort to 'real' documentation. graff jewelry data breach https://bankcollab.com

How to approach a "Got minus one from a read call" error when ...

WebApr 2, 2024 · Got minus one from a read call” is returned by the database communication layer and most possible root cause is an unexpected communication issue between the client database driver and the back-end (Oracle database) system, due the … WebSep 3, 2024 · Hi Guys, Would like to discuss one problem that I was facing today in on one of the Oracle 12c Release 1 standalone database where application team started explaining the problem that they are getting when doing application restart, specially oracle NET exception of 'Got minus one from a read call' Caused by: java.lang.RuntimeException: … WebMay 9, 2024 · JDBC - Version 19.3 and later: JDBC Connections to 19c RAC Database Fail With "Got minus one from a read call" JDBC Connections to 19c RAC Database Fail With "Got minus one from a read call" (Doc ID 2831170.1) Last updated on MAY 09, 2024. Applies to: JDBC - Version 19.3 and later Information in this document applies to … graff landscaping worth

实时数据预警规则引擎_烟感预警规则引擎-华为云

Category:[Solved] oracle.net.ns.NetException: Got minus one from a read call

Tags:Flink got minus one from a read call

Flink got minus one from a read call

DBeaver Forum • View topic - Oracle connection Settings

WebNov 6, 2012 · ERROR: [Io exception: Got minus one from a read call] INFO jvm 1 2012/11/06 15:29:05 Tried version [9.x]. ERROR: [Io exception: Got minus one from a read call] INFO jvm 1 2012/11/06 15:29:05 ) [2012-11-11 11:41:55,228][WARN ][default.com.arcsight.agent.loadable.agent._OracleAuditTrailDatabaseAgent][processQuery()] … WebJun 20, 2024 · 1 Answer. "emctl start dbconsole" is a command to start Enterprise Manager (EM), which is tool comes bundled with Oracle Database, and used for monitoring and …

Flink got minus one from a read call

Did you know?

WebApr 21, 2014 · java.sql.SQLException: Io exception: Got minus one from a read call wierd part is out 21 toracleinputs, the number of toracleinputs that extract the data is not constant sometimes 10 get extracted properly sometimes 15. We are using Talend version 5.3.1. Note: The code was working properly on oracle 11g. Thanks, WebJan 25, 2024 · Connection to ADW1 failed. [08006] [17002] IO Error: Got minus one from a read call, connect lapse 32 ms., Authentication lapse 0 ms. I have also tried using the 'Service name' and 'TNS' connection types and filled in the info from tnsnames.ora. No dice, same error. Also tried explicitely setting the 'tcp.validnode_checking' parameter to null.

WebJun 22, 2011 · Got minus one from a read call. Upon further investigation, I found that it is causing because of Oracle error: Ora:00020: Maximum number of processes exeeced (150) When i got this error, I tried to log onto Oracle, but it did not allow and refused the connection. When I restarted the J2EE server where these GRC applications are … WebOct 31, 2024 · JDBC - Version 12.1.0.2.0 and later: Got Minus One From A Read Call Error When JDBC Client Is Trying To Connect To 12c Database Over SSL

Web华为云为你分享云计算行业信息,包含产品介绍、用户指南、开发指南、最佳实践和常见问题等文档,方便快速查找定位问题与能力成长,并提供相关资料和解决方案。本页面关键词:实时数据预警规则引擎。 WebCaused by: oracle.net.ns.NetException: Got minus one from a read call at oracle.net.ns.Packet.receive(Packet.java:303) at …

WebThe "Got minus one from a read call" message points to the problem being related to max-sessions/session settings on the app and database servers. Resolution Restarting the application and database servers may resolve this problem. However, it is recommended to review the suggestions below to ensure this does not occur at a later point in time.

china brass ballcock valveWebThe immediate cause of the problem is that the JDBC driver has attempted to read from a network Socket that has been closed by "the other end". This could be due to a few things: If the remote server has been configured (e.g. in the "SQLNET.ora" file) to not accept connections from your IP. graff law llcWebMar 14, 2024 · Caused by: oracle.net.ns.NetException: Got minus one from a read call at oracle.net.ns.Packet.receive (Packet.java:314) at … graff lawn and landscapeWebJan 7, 2024 · While Connecting database 11g using sqlDeveloper getting "Status : Failure -Test failed: IO Error: Got minus one from a read call" Error. My other teammates are able to connect with the same version of sql Developer. This shows no change at database server and somewhere issue locally. Kindly provide any solution to get rid off. oracle … china brass bamboo floor lamp manufacturerWebApr 14, 2024 · FAQ - Got minus one from a read call; FAQ-读取oracle时,使用自定义表达式后,去向表找不到列; Sqoop. FAQ-Sqoop任务报错: com.mysql.jdbc.exceptions.jdbc4.Com; INFO-sqoop-update-mode相关; FAQ-sqoop --columns参数说明; FAQ-SQOOP数据倾斜; INFO-Sqoop清空mysql; INFO-Sqoop导入本 … graff legacyWebMar 22, 2015 · got minus one from a read call i tink im mising the client, but whats the client? also tnks for the help. lolipop Posts: 2 Joined: Sun Mar 22, 2015 8:40 am. Top. Re: Oracle connection Settings. by Serge » Sun Mar 22, 2015 8:33 pm . Nope, 8080 is the port for web interface. china brass badge suppliersWebThe Flink family name was found in the USA, the UK, Canada, and Scotland between 1840 and 1920. The most Flink families were found in USA in 1920. In 1840 there were 4 … china brass bamboo floor lamp suppliers